Match trailing equal sign in slurp_battery_info.
Should make it more resilient to future ambiguities in uevent.
This commit is contained in:
parent
15de209cba
commit
ac8998ef03
@ -65,21 +65,21 @@ static bool slurp_battery_info(struct battery_info *batt_info, yajl_gen json_gen
|
||||
if (*walk != '=')
|
||||
continue;
|
||||
|
||||
if (BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_NOW")) {
|
||||
if (BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_NOW=")) {
|
||||
watt_as_unit = true;
|
||||
batt_info->remaining = atoi(walk + 1);
|
||||
} else if (BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_NOW")) {
|
||||
} else if (BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_NOW=")) {
|
||||
watt_as_unit = false;
|
||||
batt_info->remaining = atoi(walk + 1);
|
||||
} else if (BEGINS_WITH(last, "POWER_SUPPLY_CURRENT_NOW"))
|
||||
} else if (BEGINS_WITH(last, "POWER_SUPPLY_CURRENT_NOW="))
|
||||
batt_info->present_rate = abs(atoi(walk + 1));
|
||||
else if (BEGINS_WITH(last, "POWER_SUPPLY_VOLTAGE_NOW"))
|
||||
else if (BEGINS_WITH(last, "POWER_SUPPLY_VOLTAGE_NOW="))
|
||||
voltage = abs(atoi(walk + 1));
|
||||
/* on some systems POWER_SUPPLY_POWER_NOW does not exist, but actually
|
||||
* it is the same as POWER_SUPPLY_CURRENT_NOW but with μWh as
|
||||
* unit instead of μAh. We will calculate it as we need it
|
||||
* later. */
|
||||
else if (BEGINS_WITH(last, "POWER_SUPPLY_POWER_NOW"))
|
||||
else if (BEGINS_WITH(last, "POWER_SUPPLY_POWER_NOW="))
|
||||
batt_info->present_rate = abs(atoi(walk + 1));
|
||||
else if (BEGINS_WITH(last, "POWER_SUPPLY_STATUS=Charging"))
|
||||
batt_info->status = CS_CHARGING;
|
||||
@ -89,11 +89,11 @@ static bool slurp_battery_info(struct battery_info *batt_info, yajl_gen json_gen
|
||||
batt_info->status = CS_DISCHARGING;
|
||||
else if (BEGINS_WITH(last, "POWER_SUPPLY_STATUS="))
|
||||
batt_info->status = CS_UNKNOWN;
|
||||
else if (BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_FULL_DESIGN") ||
|
||||
BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_FULL_DESIGN"))
|
||||
else if (BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_FULL_DESIGN=") ||
|
||||
BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_FULL_DESIGN="))
|
||||
batt_info->full_design = atoi(walk + 1);
|
||||
else if (BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_FULL") ||
|
||||
BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_FULL"))
|
||||
else if (BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_FULL=") ||
|
||||
BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_FULL="))
|
||||
batt_info->full_last = atoi(walk + 1);
|
||||
}
|
||||
|
||||
|
Loading…